Talk to us
| Parameter | Specification |
|---|---|
| Retro-Reflective Coefficient Range | 0.01500 cd/(lxm) |
| Observation Angle | 12120 (2) adjustable, precision 3, minimum division 1 |
| Incidence Angle | 0.140.0 adjustable, precision 0.5, minimum division 0.1 |
| Sample Size | 150 150 mm |
| Light Source | Standard illuminant A as per GB/T 3978 |
| Sample Reference Center to Light Aperture | 12, vertical illuminance uniformity 5% |
| Sample Reference Center to Detector Aperture | 12, vertically adjustable for 12120 observation |
| Detector Distance to Sample | 15 m |
| Wet Test Parameters | Spray nozzle 1000 mm from sample, 101 vertical angle, uniform water flow, enclosed spray chamber, water flow equivalent to 284 mm/h |
| Spray Chamber | Rigid transparent material with movable panel, 150 150 mm light channel, black-painted edges to reduce scatter |
| Spray Nozzle | Diameter 1.19 mm, connected to supply tube for stable conical water column |
| Power Supply | AC 220 V, 50 Hz, 1 kW |
| Main Console Dimensions | 900 780 1700 mm |
| Sample Table Dimensions | 630 430 1900 mm |
| Sample Table Weight | 80 kg |
| Main Console Weight | 115 kg |
| Test Environment | Dark room, temperature 20C 2C, humidity 65% 5% |
High-resolution microphotometric acquisition system for precise measurements
Infrared distance measurement for accurate positioning between main console and sample table
Wireless communication module for cable-free control and data transfer
Two measurement modes: fixed-point and scan, for flexible data acquisition
Precision motor-driven positioning with low noise
Automatic adjustment of incidence and observation angles for simplified testing
Stable light source with uniform vertical illuminance
Steady water spray system with collection trays and overflow control for wet testing
Quick-change sample fixture for efficient sample mounting
Core 32-bit multifunction mainboard for reliable control
Color touchscreen with menu-driven interface and metal keys
Automatic data output and report generation
Compatible with connected software for real-time data analysis
Enclosed dark test channel to minimize ambient light interference

Price:
Price 850.0 USD ($) / Piece
Minimum Order Quantity : 1 Piece
Usage : Leakage testing for infusion devices
Number of Specimens : 2 at a time
Test Material : Infusion sets, syringes, and related medical consumables
Temperature : 5~35C
Price 1000.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Usage : Emptying blood bags under controlled pressure
Number of Specimens : Single Specimen at a Time
Test Material : Blood bags
Temperature : 15C 35C
Price 600.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Usage : Measurement of surface friction and slip characteristics on textile samples
Number of Specimens : Single specimen each test cycle
Test Material : Textiles, fabrics, polymer films
Temperature : 10C to 40C operating range
Price 600.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Usage : Pipe Impact Resistance Testing
Number of Specimens : Single Specimen per Test
Test Material : PVC, UPVC, CPVC, HDPE Pipes
Temperature : Room temperature or as specified in the test standard