Talk to us
Testing chamber, electric control system, air source, ignition source flew control system (propane gas and air compressed gas), steel elevator, Fire extinguishing devices, emissions purification equipment (user option).
1. Equipped with a standard stainless steel ladder, conforming to the requirements of GB/T18380.31;
2. Two sample support racks are included;
3. The ladder is made of stainless steel, which is corrosion-resistant and easy to clean;
4. An air inlet port measuring 80020(W) 40010(D) is located in the lower part of the chamber, 15010mm from the front of the chamber;
5. A K-type armored thermocouple with a 2mm diameter is installed inside the chamber;
6. The airflow inside the combustion chamber can be stably controlled at (5000500) L/min.
| Feature/Specification | Details |
|---|---|
| Overall Space Size | 2500mm (length) * 3200mm (width) * 4500mm (height) |
| Material | Thermal insulation with a heat transfer coefficient of 0.7WmK, i.e., coated 65mm thick mineral fiber stainless steel plate |
| Air Source | Control gas flow through the box at (5000 500) L/min, stabilize air flow rate during test; spraying device to forcibly stop burning after test completion |
| Steel Ladder Type | Standard steel ladder width: 500mm; Wide steel ladder width: 800mm |
| Discharge Purification Device | Test box equipped with a collection and washing smoke device that does not alter air flow through the test box |
| Ignition Source | One or two belt-type propane gas burners with supporting flow meters and venturi mixers; fire supply surface drilled with 242 flat metal plates with 1.32mm diameter apertures, center distance of 3.2mm, staggered in three rows of 81. 80. and 81 holes respectively, within a nominal size of 2574.5mm; additional guide holes on each side of spout plate to maintain steady flame burning |
| a) Flow Control | Each burner equipped with a rotameter for accurate control of propane and air inflow rate |
| b) Airflow Rate (Test Conditions: 100kPa, 20) | Air: (77.7 4.8) L/min; Propane: (13.5 0.5) L/min |
| Ignition Source Position | Torch placed horizontally, (75 5) mm away from front surface of cable sample, (600 5) mm away from bottom of test box, symmetrical with axis of steel ladder; ignition point located in center between two rungs of steel ladder, at least 500mm away from lower end of sample |
| Observation Window | Tempered glass observation window surrounded by stainless steel edge |
| Exhaust System | Spiral exhaust fan; 2 sealing push and pull plates; 2.0mm stainless steel |
| Air Inlet | 1 (160mm) |
| Bottom Fixed Frame | 40mm * 40mm square tube production |

Price:
Price 4999.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Power : Other, 2200 W
Type : Other, Combustion Smoke Toxicity Gas Analysis Test System
Usage : Smoke toxicity gas measurement
Weight : 620 kg
Price 4500.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Power : Other, 220V/110V, 50Hz/60Hz, 500W
Type : Other, Digital Automated Tester
Usage : Ignition Distance Measurement for Aerosol Sprays
Weight : Approximately 35 kg
Price 8000.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Power : Other, 220240V, 50/60Hz
Type : Other, Large Scale Fire Test System
Usage : Fire Safety Testing
Weight : Approx. 2250 Kg
Price 24000.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Power : Other, 230 V AC, 50/60 Hz, 3 kW
Type : Other, Oil Burner
Usage : For burnthrough resistance testing of insulation
Weight : Approx. 85 kg