Catheter Flow Meter
Catheter Flow Meter

Catheter Flow Meter

Price 200.0 USD ($)/ Unit

MOQ : 1 Unit

Catheter Flow Meter Specification

  • Temperature
  • 15C to 40C (operating)
  • Test Material
  • Flexible & Rigid Catheters
  • Humidity
  • 10% to 90% RH (non-condensing)
  • Gas Pressure
  • 0.1-0.7 MPa
  • Number of Specimens
  • Single Specimen at a Time
  • Specimen Size
  • Catheter inner diameter: 2-8 mm
  • Test Range
  • 1-240 ml/min
  • Port Size
  • 6 mm (standard)
  • Type
  • Digital Catheter Flow Meter
  • Material
  • Stainless Steel, Precision Glass, and Polycarbonate Components
  • Power
  • 220V AC, 50/60Hz
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 600 x 400 x 1800 mm (approx.)
  • Weight
  • Approx. 48 kg
  • Usage
  • Measurement of Flow Rate in Medical Catheters
  • Application
  • Medical Device Testing, Laboratory Research, Catheter Manufacturing QC
  • Calibration
  • Auto-calibration with reference standard
  • Data Output
  • USB & RS232 connectivity for PC data transfer
  • Timer Resolution
  • 0.01 seconds
  • Compliance
  • Meets ISO 10555-1 and ASTM F640 standards
  • Software
  • Windows-based data management software included
  • Tank Capacity
  • 2 Liters (Flow Measuring Chamber)
  • Detection Method
  • Volumetric Measurement with Optical Sensors
  • Cooling System
  • Integrated cooling for temperature control
  • Display
  • Color Touch Screen Digital Display
  • Measurement Accuracy
  • 1% of reading
  • Alarm System
  • Integrated visual and sound alarm for flow errors
  • Operating Mode
  • Manual and Automatic Testing Modes
 
 

About Catheter Flow Meter

Standards

GB/T 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods

YY 0285.1 - 2017 Disposable Sterile Intravascular Catheters

Features

Independently developed hydrostatic pressure testing device, capable of maintaining a liquid level of 1000 10 mm.

Flow rate of 525 ml/min, meeting standard flow rate requirements.

Equipped with a constant temperature water bath to ensure the test water temperature is 23.

Equipped with a timer for timed testing.

Test fixture designed strictly according to standard requirements, easy to operate and highly efficient.

Uniquely designed lifting and lowering structure allows for height adjustment, facilitating testing at different water pressures.

Equipped with a balance station for convenient placement of balances or measuring cylinders.

Equipped with an adjustable precision water pump for easy flow rate adjustment.

Technical Parameters

Parameter Specification
Testing Range Usually within a weight/volume range (e.g., 1.00 - 600.00g, varying by catheter specifications) or a specific flow range
Accuracy High testing accuracy (e.g., 0.01%FS, one-ten-thousandth of full scale) or higher requirements
Static Water Level Height e.g., 2005mm, 10005mm (meets different testing needs); water pump has automatic circulation function; static water level is adjustable
Time Controller Usually 0 - 60min, with an error 1S; used to control testing time
Fixtures Adapt to various catheter specifications/types, ensuring test versatility and flexibility
Flow Calculation Generally uses the weighing method (imported flowmeters optional) to calculate flow, ensuring result accuracy
Flow Rate e.g., 525ml/min (arbitrary selection) 25ml/min, etc.; adapts to different testing scenarios
Intelligent Temperature Control Equipped with a micro-computer intelligent temperature-control system, ensuring constancy and accuracy of test temperature
Special Accessories Includes stainless-steel thermostatic water baths, special connectors, etc.; meets testing needs of different catheter specifications/types


Precision and Efficiency in Catheter Testing

This flow meter combines volumetric measurement and optical sensor technology to achieve a high accuracy of 1%. Its rapid timer resolution and integrated cooling system maintain precise conditions for reliable testing. The auto-calibration feature further ensures long-term accuracy, reducing manual intervention and supporting consistent laboratory operations.


Seamless Data Management and Compliance

Transfer measurement data easily via USB or RS232 connectivity to any PC, and analyze results using the included Windows-based software. The device fully complies with ISO 10555-1 and ASTM F640 standards, ensuring it meets regulatory requirements for medical device laboratories and manufacturing quality control.


User-Friendly, Safe, and Versatile Operation

Benefit from both manual and automatic testing modes, catering to diverse operational needs. Visual and sound alarms promptly indicate flow errors, enhancing user safety. Designed to accommodate various sample types and environments, it proves suitable across medical, research, and production settings.

FAQ's of Catheter Flow Meter:


Q: How does the Catheter Flow Meter with Display ensure accurate flow measurement?

A: The device utilizes volumetric measurement with advanced optical sensors, providing a measurement accuracy of 1% of the reading. It also features automatic calibration with a reference standard to further enhance precision and reliability.

Q: What types of catheters can be tested using this flow meter?

A: The flow meter is compatible with both flexible and rigid catheters, supporting specimen sizes with an inner diameter of 2 to 8 mm and fitting standard port sizes of 6 mm.

Q: When should the device's auto-calibration feature be used?

A: Auto-calibration runs automatically during the setup or at scheduled intervals, ensuring the device remains within its specified accuracy. No manual calibration is necessary, but it is recommended to verify calibration at the start of each testing session.

Q: Where can the Catheter Flow Meter with Display be used?

A: This instrument is ideal for use in medical device testing laboratories, catheter manufacturing quality control (QC), and research facilities focused on medical technology and fluid dynamics.

Q: What is the process for transferring and managing measurement data?

A: Data output is supported via USB and RS232 connectivity, allowing seamless transfer to a PC. The included Windows-based data management software enables storage, analysis, and reporting of flow test data.

Q: How does the integrated alarm system benefit users?

A: The system features visual and sound alarms that promptly alert users to any flow errors, ensuring immediate corrective action can be taken and maintaining testing safety and reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Textile And Apparel Testing Machine Category

Micro Rapid Closed Cup Flash Point Tester(Pensky Martens)

Micro Rapid Closed Cup Flash Point Tester(Pensky Martens)

Price 200.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Number of Specimens : One at a time

Humidity : 80% RH

Temperature : Operating: 10C35C

Test Material : Petroleum products and similar liquids

Textile Light and Heat Performance Tester

Textile Light and Heat Performance Tester

Price 1200.0 USD ($) / Set

Minimum Order Quantity : 1 Set

Number of Specimens : 1 specimen/test

Humidity : Relative Humidity: 30~80%

Temperature : Ambient: 15~35C

Test Material : Fabric/Textile

Catheter Flow Performance Testing Equipment Manufacturer

Catheter Flow Performance Testing Equipment Manufacturer

Price 400.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Number of Specimens : Single Specimen Testing

Humidity : 10%90% RH (noncondensing)

Temperature : Room Temperature to 45C (Controllable)

Test Material : All types of medical catheters

Electric rolling wheel peeling testing machine

Electric rolling wheel peeling testing machine

Price 200.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Number of Specimens : 1 specimen per test

Humidity : 85% RH (noncondensing)

Temperature : 10C35C

Test Material : Adhesive tapes, films, label materials



Back to top