Flame Spread Calorimeter
Flame Spread Calorimeter

Flame Spread Calorimeter

Price 2300.0 USD ($)/ Unit

MOQ : 1 Unit

Flame Spread Calorimeter Specification

  • Temperature
  • Room temperature, ambient 10C-35C
  • Specimen Size
  • 1050 mm 260 mm 50 mm
  • Port Size
  • 8 mm gas inlet
  • Test Range
  • 0 ~ 1500 kW/m2
  • Humidity
  • 85% RH (operational limit)
  • Test Material
  • Building materials, wallcoverings, insulation
  • Gas Pressure
  • 30 - 100 kPa (operating propane supply)
  • Number of Specimens
  • 1 (per test cycle)
  • Type
  • Bench-top Laboratory Instrument
  • Material
  • Stainless Steel, Aluminum Alloy
  • Power
  • 220V, 50Hz, 1200W
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 1200 mm 600 mm 950 mm
  • Weight
  • 170 kg
  • Usage
  • Measuring flame spread and heat release
  • Application
  • Fire Testing Laboratory, Material Research, Industrial Safety
  • Exhaust Flow Rate
  • 0 - 50 L/s adjustable
  • Oxygen Analyzer
  • Paramagnetic or equivalent high-precision
  • Compliance Standards
  • ASTM E1321, ISO 5658-1
  • Safety Features
  • Emergency shutdown, interlock system, fume extraction
  • Exhaust Duct
  • Insulated, stainless steel, 200 mm
  • Data Acquisition Interface
  • PC-based, USB connectivity with proprietary software
  • Timer Range
  • 0 - 99 min, digital display
  • Ignition Source
  • Propane gas burner
 
 

About Flame Spread Calorimeter

Application

The Flame Spread Calorimeter is suitable for:

Building materials: Evaluate flame spread and heat release performance of walls, doors, windows, ceilings, and other construction materials under fire conditions.

Rail transit: Assess fire-retardant performance of railway cars and transit facilities, ensuring compliance with safety standards.

Fire safety products: Provide flame propagation and heat release data for fire safety product certification.

Material manufacturers: Support R&D by providing flame spread and heat release data to optimize product design and performance.

Safety certification: Generate flame spread and heat release data for construction, transportation, and materials industries to support safety certification.

Parameters

Parameter Specification
Dimensions 3200 mm (L) 1100 mm (W) 2500 mm (H)
Weight 540 kg
Power Supply 220V / 380V, 50 Amps
Operating Temperature 1035C
Working Gas Compressed air from air compressor
Calibration Gases CO/CO mixture, Nitrogen, Ethylene, Compressed air
Heater System Hard-tube branch, single inlet/outlet
Filtration System Triple filtration, main filter stainless steel housing
Weighing System Capacity 6000 g
Weighing Resolution 0.01 g
Data Sampling Frequency 50 ms

Features

Integrated system: Computer and data acquisition integrated for simplified operation and increased testing efficiency.

User-friendly operation: No need to swap optical filters, enabling fast setup and testing.

Precise filtration: Triple filtration design ensures accurate and interference-free results.

High-precision weighing: 6000 g capacity with 0.01 g resolution ensures accurate mass measurement during combustion.

High-frequency sampling: 50 ms sampling frequency captures real-time and precise data.

Efficient heating and gas control: Combined heating and gas flow system provides stable thermal and flow conditions, ensuring reliable flame spread testing.



Advanced Data Acquisition with Intuitive Software

This Flame Spread Calorimeter uses a PC-based interface and proprietary software via USB, ensuring precise control and real-time data capture. The digital display and adjustable 0-99 minute timer facilitate smooth operation. High accuracy in measurement is achieved via a paramagnetic or equivalent high-precision oxygen analyzer. This technology supports detailed analysis, compliant with the latest international fire testing standards.


Robust Construction and Comprehensive Safety Measures

Built with stainless steel and aluminum alloy, the calorimeter is engineered for durability and long-term laboratory use. Integrated safety features such as an emergency shutdown switch, interlock systems, and fume extraction protect users during testing. Its insulated, stainless steel exhaust duct guarantees safe heat and fume management, while user friendliness is prioritized in both hardware and software design.


Versatile Applications in Fire Testing and Research

Ideal for fire testing laboratories, material research centers, and industrial safety settings, the calorimeter accommodates specimens up to 105026050 mm. It offers an adjustable exhaust flow rate and operates within 85% RH and 10C-35C ambient conditions, making it suitable for rigorous analytical demands. Use this instrument to gain valuable insights into flame spread dynamics and heat release, supporting compliance and innovation in safer material design.

FAQ's of Flame Spread Calorimeter:


Q: How is the Flame Spread Calorimeter used in laboratory settings?

A: The calorimeter is primarily used to measure flame spread and heat release properties of building materials, wallcoverings, and insulation. Specimens are mounted into the chamber, ignited using a propane gas burner, and data is collected via advanced sensors and PC-based software.

Q: What materials can be tested with this instrument?

A: It is designed for standardized fire testing of building materials, wallcoverings, and insulation. The specimen tray accommodates samples up to 1050 mm by 260 mm by 50 mm, suitable for a broad range of research and quality assurance applications.

Q: Where can the results from the calorimeter be applied?

A: Results are valuable for fire testing laboratories, research institutions, and industries focusing on material safety and compliance. Data from these tests assist in meeting ASTM E1321 and ISO 5658-1 requirements for product certification and regulatory compliance.

Q: What safety features are integrated into the device?

A: To ensure safe operation, the instrument includes an emergency shutdown system, interlock mechanisms, and a dedicated fume extraction system to manage heat and hazardous gases.

Q: When should calibration or maintenance be performed?

A: Regular calibration and maintenance are recommended according to usage frequency, lab protocols, and manufacturer guidelines to ensure measurement accuracy and extend equipment lifespan.

Q: How does the PC-based data acquisition interface benefit users?

A: This interface allows real-time monitoring, storage, and analysis of test data. Users can conveniently export reports for compliance documentation or further study, enhancing workflow efficiency and traceability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flammabiliy Testing Machine Category

FAA FAR 25 Appendix F Part III Oil Burner Test Apparatus

FAA FAR 25 Appendix F Part III Oil Burner Test Apparatus

Price 5000.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel Frame with Heat Resistant Components

Test Material : Aircraft Interior Panels, Insulation, Linings

Number of Specimens : Single Specimen per Test

Type : Other, Oil Burner Test Apparatus

UL 1703 Roof-Mounted PV Module Fire Performance Test Apparatus

UL 1703 Roof-Mounted PV Module Fire Performance Test Apparatus

Price 8000.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel, Aluminum Alloy Structure

Test Material : PV Modules, instructional base and support

Number of Specimens : 1 module per test

Type : Other, RoofMounted PV Module Fire Performance Test Apparatus

Tracking Index Tester

Tracking Index Tester

Price 900.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel & HighGrade Plastic

Test Material : Solid Electrical Insulating Materials

Number of Specimens : 1

Type : Other, Testing Equipment

ISO 14001 Combustion Flue Gas Emission Treatment System for Lab Furnaces

ISO 14001 Combustion Flue Gas Emission Treatment System for Lab Furnaces

Price 1500.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Highgrade Alloy Steel and Corrosionresistant Coatings

Test Material : Labcombusted materials, various industrial and R&D samples

Number of Specimens : Multistream connections possible, up to 4 lab furnace lines

Type : Other, Combustion Flue Gas Emission Treatment System



Back to top