Flammability Limits Tester
Flammability Limits Tester

Flammability Limits Tester

Price 2800.0 USD ($)/ Unit

MOQ : 1 Unit

Flammability Limits Tester Specification

  • Temperature
  • Ambient to 50C
  • Test Material
  • Various gases and vapors
  • Number of Specimens
  • Single specimen per test
  • Port Size
  • 1/4 inch
  • Gas Pressure
  • 0 - 0.2 MPa
  • Test Range
  • Up to 100% LEL (Lower Explosive Limit)
  • Humidity
  • 40% - 85% RH
  • Specimen Size
  • Standard as per ASTM/ISO method
  • Type
  • Flammability Limits Tester
  • Material
  • Stainless Steel
  • Power
  • 220V, 50/60Hz
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 600 x 400 x 450 mm
  • Weight
  • Approx. 28 kg
  • Usage
  • Laboratory Testing Equipment
  • Application
  • Determining the flammability limits of gases and vapors in air
  • Accessories Included
  • Pressure regulator, sample holder, documentation
  • Control Method
  • Manual and programmable controls
  • Ignition Source
  • Electronic ignition system
  • Safety Features
  • Overpressure protection, flame shield, emergency shut-off
  • Calibration
  • Factory calibrated, user recalibration possible
  • Display
  • Digital readout for monitoring parameters
 
 

About Flammability Limits Tester

Application

The Flammability Limits Tester is suitable for:

Determining the upper and lower flammability limits of chemical gases and vapors.

Safety evaluation of industrial gas mixtures in laboratories and production facilities.

Research on combustible gas behavior under controlled temperature and pressure conditions.

Specific Testing Equipment:

Combustible gas sample containers

Gas mixing and vacuum control modules

Ignition control systems

Temperature and pressure monitoring devices

Standards

The system complies with the following national and international standards:

GB/T 21844-2008 Standard Test Method for Flammability Limits of Compounds (Vapors and Gases) (China)

ASTM E918-19 Standard Test Method for Flammability Limits of Chemicals at Elevated Temperatures and Pressures

ISO 10156 Gases and Gas Mixtures Determination of Flammability Limits

EN 1839 Determination of Flammability Limits of Gaseous Fuels

Parameters

Unit Specification
Environmental Temperature Adjustable: ambient 200C, control accuracy 1C
Sealed Container Standard 8L stainless steel vessel
High-Precision Pressure Sensor Range: 0200kPa (absolute), for precise gas mixing
Conventional Pressure Sensor Range: -0.13MPa, for auxiliary container pressure monitoring
Auxiliary Gas Source Air / Nitrogen / Test gas
Dimensions 800(W) 600(D) 1300(H)mm
Power Supply AC 220V, 50/60Hz, 10A
Weight Approx. 150kg


Advanced Control and Display

With a user-friendly digital readout, this tester allows for easy monitoring of key parameters during testing. Users can choose between manual control for straightforward operation or programmable settings for repeatable, automated test sequences, ensuring consistent and accurate results every time.


Comprehensive Safety Features

Safety is a core aspect of the design, featuring overpressure protection, a sturdy flame shield, and an emergency shut-off mechanism. These elements safeguard the user, equipment, and environment during testing procedures, offering peace of mind and compliance with laboratory safety standards.

FAQ's of Flammability Limits Tester:


Q: How does the electronic ignition system enhance the testing process?

A: The electronic ignition system ensures reliable and consistent ignition of gas samples, reducing user involvement and increasing test repeatability. This automated approach minimizes the risk of human error and provides a safer environment during flammability limit determination.

Q: What parameters can be monitored on the digital display?

A: The digital readout provides real-time monitoring of key test conditions such as pressure, temperature, and sample status. This clear display helps operators keep track of vital information throughout the experiment, improving accuracy and efficiency.

Q: When should user recalibration be performed?

A: Although the tester is factory calibrated for immediate use, periodic recalibration is recommended, especially after extensive operation or exposure to harsh conditions. Regular calibration ensures ongoing measurement accuracy and reliability.

Q: Where is the Flammability Limits Tester typically used?

A: This tester is ideal for laboratory environments in industries such as chemical manufacturing, quality control, research and development, and safety compliance testing. Its robust design and safety features make it suitable for both academic and industrial settings.

Q: What is the process for using manual and programmable controls?

A: Operators can manually adjust settings for straightforward, user-directed tests, or utilize programmable controls for automated, repeatable procedures. This flexibility allows users to tailor the testing process to specific requirements and ensures reproducibility across different test runs.

Q: How do the included accessories support testing?

A: Accessories such as the pressure regulator and sample holder streamline the setup process, ensuring secure sample containment and precise pressure control. The included documentation provides detailed guidance for installation, operation, and maintenance, enhancing user confidence and ease of use.

Q: What are the key benefits of the built-in safety features?

A: The overpressure protection, flame shield, and emergency shut-off functions work together to prevent accidents, equipment damage, and potential hazards. These features promote a safer working environment, making the tester suitable for stringent laboratory and industrial safety standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flammabiliy Testing Machine Category

Battery combustion tester

Battery combustion tester

Price 1500.0 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Material : Stainless Steel

Test Material : Battery or battery pack

Temperature : Room Temperature to 40C

Number of Specimens : 1 specimen per test

Battery Abuse Testing Chamber

Battery Abuse Testing Chamber

Price 3800.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Test Material : Liion battery, LeadAcid battery, NiMH battery

Temperature : Room Temp to 110C

Number of Specimens : Up to 2 at once

Tracking Index Tester

Tracking Index Tester

Price 900.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel & HighGrade Plastic

Test Material : Solid Electrical Insulating Materials

Temperature : 20C 30C

Number of Specimens : 1

Flame Retardant Paper and Board Combustion Tester

Flame Retardant Paper and Board Combustion Tester

Price 750.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel and Heatresistant Glass

Test Material : Paper and Board Samples

Temperature : Room Temperature (15~35C)

Number of Specimens : Single Specimen Test