Multi-Function Thermal Conductivity Measurement Platform Specification

  • Resolution
  • 0.001 W/mK
  • Equipment Type
  • Thermal Conductivity Measurement Platform
  • Features
  • Multi-function, rapid measurement, precise control, compact design
  • Number of Specimens
  • 1 at a time
  • Frequency
  • 50 Hz
  • Gas Pressure
  • Up to 6 bar
  • Interface Type
  • USB/RS232
  • Mounting Type
  • Bench-top
  • Accuracy
  • 2%
  • Measuring Range
  • 0.01 - 20 W/mK
  • Automation Grade
  • Automatic
  • Port Size
  • Standard (1/4 inch) Connection
  • Temperature
  • Room Temperature to 300C
  • Response Time
  • <60s
  • Power Supply
  • 220V AC, 50 Hz
  • Operating Voltage
  • 220V AC
  • Test Range
  • 0.01 to 20 W/mK
  • Application
  • Measurement of thermal conductivity for various materials
  • Specimen Size
  • Diameter: 50 mm (standard), Thickness: 1 - 10 mm
  • Max Height
  • 200 mm
  • Display Type
  • Digital LCD
  • Humidity
  • 10 - 90% RH (Non-Condensing)
  • Usage
  • Thermal property analysis, laboratory or industrial use
  • Capacity
  • Single measurement
  • Machine Weight
  • Approx. 25 kg
  • Test Speed
  • Variable, 0.1 - 10 mm/min
  • Test Width
  • Up to 100 mm sample width
  • Test Stroke
  • 0 - 50 mm
  • Control Mode
  • Automatic & Manual Switchable
  • Noise Level
  • <55 dB
  • Environmental Compliance
  • RoHS and CE certified
  • Software Support
  • Windows-based analysis software included
  • Heating Method
  • Electric heating plate
  • Data Logging
  • Internal storage & external export
  • Safety Features
  • Over-temperature and pressure protection
  • Calibration
  • Factory calibrated with reference materials
  • Sample Preparation Time
  • Less than 2 minutes per specimen
  • Cooling Method
  • Fan-cooled
 
 

About Multi-Function Thermal Conductivity Measurement Platform

Application

The Multi-Function Thermal Conductivity Measurement Platform is suitable for thermal property evaluation in research, quality control, and material development, including:

Polymers, composites, and building materials

Liquids and phase-change materials

Pastes, powders, and bulk solids

Soil and polymeric materials

Typical test samples include solid blocks and plates, liquid samples, powders, pastes, and soil specimens, depending on the selected sensor and test method.

Standards

The platform supports internationally recognized absolute measurement standards, including:

(1) ISO 22007-2: Plastics Determination of thermal conductivity and thermal diffusivity Transient plane heat source method

(2) ISO 22007-7: Plastics Determination of thermal conductivity and thermal diffusivity using transient plane heat source

(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials

(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method

(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids

(6) ASTM D5334: Transient line-source probe method

(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique

Parameters

Method TPS THW MTPS TLS
Applicable Materials Solids, pastes, powders Liquids, phase-change materials Solids, pastes, powders Soil, pastes, polymers
Measurement Module 3D bulk, anisotropic, plate, thin film; general: specific heat Bulk 3D bulk, anisotropic, plate; 1D standard Bulk
Thermal Conductivity (W/mK) 0.01500 0.012 0.03500 0.18
Thermal Diffusivity (mm/s) 0.01300 Up to 0.5 0.01300 Not applicable
Volumetric Heat Capacity (MJ/mK) Up to 5 Up to 5 Up to 5 Not applicable
Thermal Effusivity (Ws/mK) 2040000 Not applicable 2040000 Not applicable
Sample Size (mm mL) 10 or square 20 mL 25 or square
Sample Thickness (mm) 0.05 Not applicable 0.1 Probe length 100
Maximum Sample Size Unlimited Unlimited Unlimited Unlimited
Test Time (s) 2160 1 2160 180
Accuracy (Thermal Conductivity) 5% 2% 5% 5%
Repeatability (Thermal Conductivity) 2% 1% 2% 2%
Temperature Range (C) 0300 / 75300 50200 0100 / 50200 40100
Sample Configuration Symmetric / asymmetric Insert type Asymmetric (single-sided) Insert type
Supported Standards ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 ASTM D7896 ISO 22007-7 ASTM D5334. ASTM D5930


Accurate and Reliable Measurements

Factory-calibrated with reference materials, this platform delivers highly accurate results within a 2% margin. Its advanced control systems and high-resolution (0.001 W/mK) readings ensure dependable performance for laboratory or industrial applications.


Effortless Data Management and Analysis

Seamlessly log and export measurement data through USB or RS232. The included Windows-based software provides powerful tools for advanced analysis, reporting, and data archiving, supporting improved productivity and traceability.


Safe, Quiet, and Environmentally Compliant

Featuring over-temperature and pressure protection, this RoHS and CE certified equipment operates safely in diverse environments. The low noise level (<55 dB) and compact bench-top design make it ideal for laboratory and industrial settings alike.

FAQ's of Multi-Function Thermal Conductivity Measurement Platform:


Q: How do I prepare a specimen for measurement using this platform?

A: Specimen preparation requires less than two minutes per sample. Simply cut or select a specimen with a 50 mm diameter and a thickness between 1 and 10 mm, ensuring it fits within the sample chamber before initiating the test.

Q: What materials can be analyzed with this thermal conductivity measurement platform?

A: The platform is designed to measure a wide range of materials, including solids such as metals, polymers, ceramics, and composites, within a range of 0.01 to 20 W/mK thermal conductivity.

Q: When should calibration be performed on the equipment?

A: Each instrument comes factory calibrated with reference materials. Calibration is not frequently required, but annual verification or recalibration is recommended to maintain optimal measurement accuracy.

Q: Where can the data from measurements be stored or exported?

A: Measurement data can be internally stored within the device or easily exported through USB/RS232 interfaces for further analysis on a Windows computer using the supplied software.

Q: What safety features are integrated into the platform?

A: The device includes over-temperature and over-pressure protection systems to ensure operational safety for both users and samples, complying with RoHS and CE standards.

Q: How does the variable test speed benefit the measurement process?

A: Variable test speed, adjustable from 0.1 to 10 mm/min, allows users to optimize the testing process based on material type and desired accuracy, enhancing flexibility and productivity.

Q: What are the main usage benefits of this equipment for laboratories or industrial applications?

A: The platform offers rapid, automatic, and precise thermal conductivity measurements, enabling efficient workflow, robust data management, and reliable compliance with international standards. Its compact design and low operational noise further support versatile use in different settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Materials Testing Machines Category

Spring Torsion Test Machine for Mechanical Properties Testing

Spring Torsion Test Machine for Mechanical Properties Testing

Price 400.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Specimen Size : Various (customized grips available)

Max Height : 300 mm

Test Stroke : Max 200 mm

Application : Testing mechanical properties of springs

Automated Geomembrane Vertical Load Performance Tester

Automated Geomembrane Vertical Load Performance Tester

Price 600.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Specimen Size : 100 x 100 mm

Max Height : 900 mm

Test Stroke : 0200 mm

Application : Vertical load performance and deformation test for geomembrane materials.

Electric Pencil Hardness Tester ASTM D3363 Standard

Electric Pencil Hardness Tester ASTM D3363 Standard

Price 300.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Specimen Size : Up to 100 50 mm

Max Height : Approx. 200 mm

Test Stroke : 060 mm

Application : Surface hardness testing for coatings, paints, lacquer, plastic, etc. (ASTM D3363)

High Precision Connector Waterproof Air Tightness Testing Equipment

High Precision Connector Waterproof Air Tightness Testing Equipment

Price 500.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Specimen Size : Customizable

Max Height : 180 mm

Test Stroke : 10150 mm

Application : Connector waterproof and air tightness testing



Back to top