Talk to us
The Multi-Function Thermal Constants Analyzer is used for quantitative thermal property evaluation in various material forms and industries, including:
Polymers, composites, and construction materials
Liquids, phase-change materials, and coolants
Pastes, powders, and bulk solids
Soil, polymers, and anisotropic materials
Typical test samples include solid plates, bulk materials, liquids in containers, pastes, powders, and soil samples, depending on the selected measurement method.
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics Determination of thermal conductivity and thermal diffusivity Transient plane heat source method
(2) ISO 22007-7: Plastics Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/mK) | 0.0052000 | 0.012 | 0.03500 | 0.012 | |
| Thermal Diffusivity (mm/s) | 0.011200 | Up to 0.5 | 0.01300 | Up to 0.5 | |
| Volumetric Heat Capacity (MJ/mK) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | |
| Thermal Effusivity (Ws/mK) | 560000 | Not applicable | 2040000 | Not applicable | |
| Contact Thermal Resistance (mK/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | 0.01 | 0.1 | |||
| Test Time (s) | 0.252560 | 1 | 0.252560 | 0.252560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (C) | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / 50 to 200 | 75 to 300 | 40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |

Price:
Price 1000.0 USD ($) / Set
Minimum Order Quantity : 1 Set
Response Time : Instantaneous
Temperature : 5C~40C (ambient)
Accuracy : 1 N
Application : Battery nail penetration safety testing
Price 600.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Response Time : Instantaneous
Temperature : 10~35C
Accuracy : 1 mm
Application : Battery safety impact/crush testing
Price 3000.0 USD ($) / Piece
Minimum Order Quantity : 1 Piece
Response Time : <2 seconds
Temperature : Room Temperature to 70C
Accuracy : 0.5%
Application : Biodegradability Testing of Plastic Samples
Price 6000.0 USD ($) / Unit
Minimum Order Quantity : 1 Unit
Response Time : 10 ms
Temperature : Room temperature (10~35C)
Accuracy : 1% F.S.
Application : Fatigue and mechanical testing of dental implants and abutments