Ozone Aging Chamber
Ozone Aging Chamber

Ozone Aging Chamber

Price 500.0 USD ($)/ Unit

MOQ : 1 Unit

Ozone Aging Chamber Specification

  • Number of Specimens
  • Up to 12
  • Interface Type
  • Digital/RS232 (optional)
  • Application
  • Accelerated ozone aging testing for rubber, plastics and elastomers
  • Gas Pressure
  • 0.2-0.3 MPa
  • Humidity
  • 40-85% RH (Controllable)
  • Mounting Type
  • Floor-mounted, with lockable casters
  • Temperature
  • Room temp. to 100C (0.5C)
  • Max Height
  • Approx. 1600 mm
  • Measuring Range
  • Ozone: 0-300 pphm
  • Power Supply
  • 220V AC, 50/60Hz
  • Display Type
  • LCD Digital Display
  • Accuracy
  • 5% F.S.
  • Frequency
  • 50/60Hz
  • Resolution
  • 0.1 pphm Ozone
  • Port Size
  • Standard 25mm; others customizable
  • Equipment Type
  • Ozone Aging Chamber
  • Automation Grade
  • Automatic
  • Specimen Size
  • Standard: 10 150 mm (other sizes optional)
  • Response Time
  • 30 seconds
  • Features
  • Automatic control, Overheat protection, Programmable timer, Safety interlock
  • Test Range
  • 0-300 pphm Ozone Concentration
  • Operating Voltage
  • 220V
  • Usage
  • Industrial Laboratory Testing
  • Capacity
  • 150 Liters (Optional sizes available)
  • Machine Weight
  • Approx. 180 kg
  • Test Speed
  • 10-20 RPM (Adjustable)
  • Test Width
  • Customizable as per requirement
  • Test Stroke
  • Standard rotation, adjustable
  • Control Mode
  • Microprocessor-based PID Control
  • Timer Range
  • Programmable up to 999 hours
  • Door Type
  • Airtight hinged door with observation window
  • Safety Features
  • Overcurrent and overtemperature protection, door safety interlock
  • Chamber Material
  • Inner SUS#304 Stainless Steel, Outer Steel with powder coating
  • Mobility
  • Equipped with heavy-duty swivel wheels
  • Ambient Temperature
  • 5C - 35C operating environment
  • Ozone Generation Method
  • Corona Discharge System
  • Controller Brand
  • Imported programmable controller
 
 

About Ozone Aging Chamber

Standards

GB/T 11039.3-2005 Textiles - Color fastness tests - Resistance to atmospheric pollutants - Part 3: Atmospheric ozone

ISO 105-G03:1993 Textiles - Colour fastness tests - Part G03: Resistance to atmospheric ozone

GB/T 7762-2014 Vulcanized rubber or thermoplastic rubber - Resistance to ozone cracking - Static tensile test

GB/T 13642-2015 Vulcanized Rubber or Thermoplastic Rubber - Resistance to Ozone Cracking - Dynamic Tensile Test

AATCC 109-2016 Resistance to Ozone in Low-Humidity Atmosphere

AATCC TM129-2011(2016)e Test Method for Resistance to Ozone in High-Humidity Atmosphere

Features

High-Efficiency Ozone Generation: Ensures stable and uniform ozone concentration for consistent test results.

Closed-Loop Ozone Control: Automatically monitors and maintains the desired ozone levels during testing.

Rotating Sample Rack: Accommodates up to 24 specimens, ensuring uniform exposure to ozone.

User-Friendly Interface: Pre-set and current parameters are displayed on-screen for easy operation and monitoring.

Colorfastness Assessment: Simultaneously tests one specimen against a control standard to determine ozone-induced fading.

Flexible Environmental Simulation: Supports both low- and high-humidity ozone aging tests.

Parameters

Item Specifications
Control Mode Automatic
Ozone Range 11000 ppm
Sample Rack Rotation Speed 110 RPM (adjustable)
Sample Fixture Material Stainless steel
Main Body Material Stainless steel
Weight 155 kg
Power Supply 220V 50Hz
Overall Dimensions (LWH) 1020mm1000mm1650mm


Reliable Testing for Material Durability

The chamber simulates harsh ozone-rich environments to evaluate the aging performance of materials, including rubber and plastics, ensuring products maintain quality and longevity in real-world conditions. Robust construction and advanced programmability make it ideal for both research and industrial quality assurance.


User-Friendly Automated Operation

With a microprocessor-based PID controller, engineers can easily set and monitor testing cycles using the LCD digital display. The programmable timer supports extended duration tests of up to 999 hours, and safety features ensure secure operation throughout the testing process.

FAQ's of Ozone Aging Chamber:


Q: How does the Ozone Aging Chamber work for testing rubber and plastics?

A: The chamber utilizes corona discharge to generate ozone, exposing specimens to controlled ozone concentrations within a programmable temperature and humidity environment. This accelerated process simulates years of natural aging within days or weeks, helping assess material resistance to ozone degradation.

Q: What benefits does the chamber's programmable controller provide?

A: The imported programmable controller enables precise adjustment of test parameters such as ozone concentration, temperature, humidity, timer settings, and test speed. This automation ensures consistent test conditions and reproducible results, enhancing testing efficiency and data reliability.

Q: When should an ozone aging chamber be used in a product's lifecycle?

A: It is ideally used during research and development phases, product qualification, and quality assurance testing to evaluate the long-term durability of elastomers, rubber, or plastic components before they are launched to market.

Q: What safety measures are implemented in this chamber?

A: The chamber includes overcurrent and overtemperature protection, a door safety interlock, and automatic system shutdown in case of abnormal conditions, ensuring personnel and specimen safety during operation.

Q: Where can the Ozone Aging Chamber be installed?

A: This floor-mounted unit, featuring heavy-duty lockable casters, is suitable for industrial laboratories and research facilities with ambient temperatures between 5C-35C. Its robust construction and mobility allow flexible placement as testing needs change.

Q: What is the process for conducting a specimen test in the chamber?

A: Specimens are mounted in the chamber, test parameters are set using the digital controller, and the airtight door is sealed. The chamber automatically runs the programmed test cycle, after which results can be evaluated using the digital display or optional RS232 interface.

Q: What are the usage benefits of this ozone aging chamber for manufacturers?

A: Manufacturers gain accurate insight into material aging, enabling them to improve material formulations, ensure compliance with international standards, and enhance product longevity, thus reducing warranty claims and boosting customer satisfaction.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Weathering And Light Stability Testing Machine Category

Photovoltaic module damp heat test chamber

Photovoltaic module damp heat test chamber

Price 2000.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Usage : PV module endurance and qualification testing

Application : Accelerated damp heat testing of photovoltaic modules

Number of Specimens : Up to 6 standard PV modules

Interface Type : RS485 / USB data export

Altitude Simulation Test Chamber MIL STD 810 Manufacturer

Altitude Simulation Test Chamber MIL STD 810 Manufacturer

Price 15000.0 USD ($) / Set

Minimum Order Quantity : 1 Set

Usage : Simulation of high altitude environment for product testing

Application : Environmental testing under high altitude conditions

Number of Specimens : 1~10 (based on size)

Interface Type : Ethernet, USB, RS232

Weathering And Light Stability Testing Machine

Weathering And Light Stability Testing Machine

Price 500.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Usage : Research labs, quality control, industrial testing

Application : Accelerated weathering, light fastness, and photostability tests for polymers, textiles, paints, plastics, rubbers, etc.

Number of Specimens : Up to 24

Interface Type : USB and RS232

Transparent Absorbing Wave Temperature and Humidity Vibration Test Chamber

Transparent Absorbing Wave Temperature and Humidity Vibration Test Chamber

Minimum Order Quantity : 1 Unit

Usage : Product reliability and component testing

Application : Simultaneous environmental testing (temperature, humidity, vibration)

Number of Specimens : 1 ~ 6 (adjustable)

Interface Type : RS232 / USB



Back to top