Rapid screening Calorimeter
Rapid screening Calorimeter

Rapid screening Calorimeter

Price 7000.0 USD ($)/ Unit

MOQ : 1 Unit

Rapid screening Calorimeter Specification

  • Gas Pressure
  • Max 100 bar
  • Temperature
  • Room Temperature to 500C
  • Specimen Size
  • Approximately 2-10 ml
  • Test Range
  • Ambient to 500C
  • Test Material
  • Solid, liquid, slurry, paste
  • Port Size
  • 1/4 NPT female
  • Number of Specimens
  • 1 (single cell)
  • Humidity
  • 0-95% RH (non-condensing)
  • Type
  • Rapid Screening Calorimeter
  • Material
  • Stainless Steel, High-grade Alloys
  • Power
  • 220V/50Hz, 800W
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 550 mm x 600 mm x 850 mm
  • Weight
  • Approx. 58 kg
  • Usage
  • Thermal hazard screening, process safety evaluation
  • Application
  • Chemical, Pharmaceutical, Research Laboratories
  • Data Output Interface
  • USB, Ethernet
  • Pressure Transducer
  • Piezoelectric, range up to 100 bar, accuracy 0.2% F.S.
  • Safety Features
  • Automatic pressure release, over-temperature protection, alarm system
  • Cooling System
  • Integrated forced-air or water-cooled options
  • Control System
  • Microprocessor-based controller with color display
  • Display
  • 7-inch touchscreen
  • Compliance
  • CE, ISO 9001:2015 certified
  • Explosion Containment
  • Designed up to 120 bar for advanced screening
  • Resolution
  • Temperature: 0.1C, Pressure: 0.01 bar
  • Sample Vessel Material
  • 316L Stainless Steel, PTFE liner compatible
  • User Calibration
  • User-calibration feature for temperature and pressure
  • Software
  • Windows-based control and analysis suite
  • Heating Rate
  • Up to 50C/min programmable
  • Operating Environment
  • 10-40C, <80% RH (non-condensing)
 
 

About Rapid screening Calorimeter

Standards

(1)SN/T 3078.1: Standard Sample Management Specifications for Import and Export Commodity Inspection - Part 1: General Provisions

(2)NY/T 3784: Determination of Vanillin, Ethyl Vanillin, Maltol, and Ethyl Maltol in Feed - High Performance Liquid Chromatography

(3)GB 51283: Engineering Design Standard for Raw Material Yards in Iron and Steel Enterprises

Features

(1)Dual - channel design makes testing more efficient and accurate.

(2) It provides large - sample - quantity data and pressure data, which are not available in DSC/DTA (Differential Scanning Calorimetry/Differential Thermal Analysis).

(3) Key components are from well - known international brands, ensuring the long - term and stable operation of the instrument.

(4) It supports constant - temperature mode, scanning mode, and double - gradient scanning mode.

(5)Equipped with professional data - analysis software, it can provide data such as the starting points of temperature/pressure sudden changes, peak temperature/pressure, temperature/pressure rise rates, and reaction heat.

(6)It has an experimental status indication function, as well as overpressure and over - temperature alarm functions.

(7)After the experiment, an inert gas can be introduced to rapidly cool down the furnace body.

(8)The furnace cover has an automatic locking function and can only be opened when the pressure and temperature inside the furnace are within the safe range. 9. With professional industrial design, it is simple and elegant.

Technical Parameters

Operating environment

(540), <85%RH

Temperature control range

Room temperature400

Rising rate

(0.510)/min

Temperature resolution

0.01

Pressure range

(020)MPa

Pressure resolution

1kPa

Detection sensitivity

1%DTBP@6ml Toluene

Sample cell specifications

8mL

Sample cell material

Stainless steel, Titanium, Hastelloy (optional)

Interfaces

RJ45

Power supply

AC220V/50Hz

Power

800W

Dimensions

310mm*280mm*350mm

Weight

15.5kg



Advanced Control and Display System

Powered by a microprocessor-based controller and a large 7-inch touchscreen, this calorimeter enables intuitive operation and precise programming for heating rates up to 50C/min. The Windows-based software suite allows seamless control, analysis, and data export, enhancing user productivity and ease of use.


High Safety and Flexibility

Featuring explosion containment up to 120 bar, automatic pressure release, and an integrated alarm system, the calorimeter ensures the highest safety levels during testing. Over-temperature protection, user-calibration options, and both forced-air or water cooling further expand its operational versatility.


Robust Sample Compatibility

The testing vessel, constructed from corrosion-resistant 316L stainless steel with optional PTFE liner, accommodates solid, liquid, slurry, and paste samples from 2-10 ml. A piezoelectric transducer with 0.2% F.S. accuracy measures pressures up to 100 bar, supporting reliable testing for a variety of applications.

FAQ's of Rapid screening Calorimeter:


Q: How does the Rapid Screening Calorimeter ensure operator safety during use?

A: The unit incorporates automatic pressure release, over-temperature protection, and an integrated alarm system. Its explosion containment is designed up to 120 bar, providing a secure environment even under challenging test conditions.

Q: What types of samples and processes can this calorimeter handle?

A: The calorimeter is compatible with solid, liquid, slurry, and paste samples in single-cell configurations. It is ideal for thermal hazard screening, reaction study, and process safety evaluations within research, chemical, and pharmaceutical laboratories.

Q: Where can the data collected by the calorimeter be exported or analyzed?

A: Data output interfaces include USB and Ethernet ports, allowing easy export for analysis. The provided Windows-based control and analysis suite further enhances detailed assessment and data management.

Q: When should user calibration be performed on the instrument?

A: User calibration for temperature and pressure should be done regularly based on your laboratory protocols or whenever high-precision results are required to maintain measurement accuracy within the specifications.

Q: What are the benefits of having both forced-air and water-cooled options in the cooling system?

A: Dual cooling options provide flexibility for different experiment requirements, improve temperature control, and enable efficient heat dissipation, particularly during high-energy reactions or when rapid cooldown is necessary.

Q: How is the sample vessel designed to withstand harsh chemicals and prevent contamination?

A: Made from 316L stainless steel with compatibility for PTFE liners, the vessel offers excellent chemical resistance, minimizing contamination risk and ensuring accurate results even with aggressive test materials.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Textile And Apparel Testing Machine Category

Nasal Oxygen Cannula Airflow Resistance Tester ISO 5367

Nasal Oxygen Cannula Airflow Resistance Tester ISO 5367

Price 600.0 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Number of Specimens : Single (1 specimen per test)

Weight : 28 kg

Humidity : 80% RH

Dimension (L*W*H) : 530 x 400 x 390 mm

Safety Helmet Molten Metal Splash Resistance Tester

Safety Helmet Molten Metal Splash Resistance Tester

Price 799.0 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Number of Specimens : 1 piece per test cycle

Weight : Approximately 150 kg

Humidity : <80% RH

Dimension (L*W*H) : 1200 x 600 x 1500 mm

Glass Bottle Internal Pressure Resistance Tester ASTM C147

Glass Bottle Internal Pressure Resistance Tester ASTM C147

Price 600.0 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Number of Specimens : 1 specimen per cycle

Weight : Approx. 60 kg

Humidity : 10~90%RH

Dimension (L*W*H) : 600mm x 400mm x 650mm

Photoluminescent Afterglow Performance Measurement System DIN 67510 Standard

Photoluminescent Afterglow Performance Measurement System DIN 67510 Standard

Price 200.0 USD ($) / Unit

Minimum Order Quantity : 1 Unit

Number of Specimens : 1 (standard); Optional multiple sample holders available

Weight : 55 kg (approx.)

Humidity : Up to 85% RH (Noncondensing)

Dimension (L*W*H) : 550 mm x 550 mm x 600 mm



Back to top